NOTICEThis equipment has been tested and found comply with the limits fora Class A digital device, pursuant to part 15 of the FCC Rules.These limits a
You can change factoryinterface default for other typeinterface. By plug differentcable, program scanner andset right interface to exit, thenthe scann
LowCZA*CZA*MediumCZB*CZB*HighCZC*CZC*TurboCZD*CZD*Numeric Key PositionCaps LockKeyboard SpeedFunction Key SimulationBy selecting, you can changeoutput
Specific AdjustmentsBALInter-char. Delay*BAL*(Range:0010-9910 Unit:1ms)BAMTransmit Delay*BAM*(Range:0010-9910 Unit:10ms)Keyboard SimulationSpare Funct
Select keyboard type connector ofyour host computer. Scanner must beselected to the appropriate hostinterface cable converter. Refer toCable Type at /
Keyboard LayoutThe selecting of keyboard layoutsupports many country languagesother than USA keyboard layout. Firstyou need to confirm country langage
Handshaking ProtocolCTS: Clear To Send (Hardware Signal)RTS: Request To Send (Hardware Signal)STX: Start Of Text (ASCII Code 0216)ETX: End Of Text (AS
Data ParityBaud RateDHA38400 Bps*DHA*DHB19200 Bps*DHB*DHC9600 Bps*DHC*DHD4800 Bps*DHD*DHE2400 Bps*DHE*DHF1200 Bps*DHF*DHG600 Bps*DHG*DHH300 Bps*DHH*DK
Inter-char. Delay: It is delay timebetween data character's output. It issame as Inter-char. Delay of keyboardwedge, see /12.Transmit Delay: It
Active LevelNormal LevelNarrow/Wide RatioOutput SpeedDOALow*DOA*DOBMedium*DOB*DOCHigh*DOC*DODTurbo*DOD*Bar Hi/Space Lo: Black will betransmited as a h
Discrete codes such as Code-39and Codabar are featured an Inter-Char. Gap between two characters ofbarcode. It makes them suitable forprinting in the
Operation Manual2
Protocol TypeData ParitySpecific AdjustmentsSpare FunctionTansmit Delay: It is a delay timebetween barcode data output. It is alsothe same as Transm
After power-on the scanner willgenerate music to indicate thesuccessful selftest. You can inhibit themusic by setting D isable.By setting Enable, the
Inter-char. GapDouble ConfirmCase ConversionField ControlSpare FunctionThe scanner will require manytimes of successful decoding toconfirm the barcode
Scanning ModeGood-read Off: The trigger buttonmust be pressed to active scanning.The light source of scanner stopsscanning when there is a successfulr
Specific AdjustmentsBeep Adjustments: You can adjustBeep Loudness, Beep Tone andBeep Duration of good reading uponyour pavorite usage.Stand-by Time: A
Specific AdjustmentsAdd-on Waiting Time: This setting isonly used for reading WPCsymbologies with Add-on, such asEAN and UPC. The WPC must bedecoded f
ReadAdd-onWaiting Add-onCheck Digit TransmissionFormatLeadingZeroData Digts(11 Digits)CheckDigitThe Add-on barcode is thesupplemental 2 or 5 character
The leading "0" digits of barcodedata characters can be truncatedwhen the function is enabled.Example Barcode "00054321"Output &q
ReadAdd-onWaiting Add-onExpansionFormatLeadingZeroData Digits(6 Digits)CheckDigitFormatLeadingZeroData Digits(6 Digits)CheckDigitAdd-on2 or 5Refer to
Refer to /26.Refer to /27.Refer to /27.DisableEGA*EGA*EnableEGB*EGB*Truncate LeadingBAQ*BAQ*(Range:0010-1510)Truncate EndingBAR*BAR*(Range:0010-1510)C
Index1 Instroduction«««««««««««««««««««««««««««««««««««««««««««««««« 4Installation«««««««««««««««««««««««««««««««««««4Recommended Steps ««««««««««««««
ReadWaiting Add-onISBN/ISSN ConversionAdd-onFormatData Digts(12 Digits)CheckDigitFormatData Digits(12 Digits)CheckDigitAdd-on2 or 5Refer to /26.The IS
Refer to /26.Refer to /27.Refer to /27.DisableEQA*EQA*EnableEQB*EQB*DisableEOA*EOA*EnableEOB*EOB*Truncate LeadingBAS*BAS*(Range:0010-1510)Truncate End
ReadAdd-onWaiting Add-onExpansionExpansionFormatData Digits(7 Digits)CheckDigitFormatData Digits(7 Digits)CheckDigitAdd-on2 or 5Refer to /26.Refer to
Refer to /26.Refer to /27Refer to /27.DisableEYA*EYA*EnableEYB*EYB*DisableEWA*EWA*EnableEWB*EWB*Truncate LeadingBAU*BAU*(Range:0010-1510)Truncate Endi
ReadFormatCode-32 TranslationStart/End TransmissionAppendFormatStart"V"Data Digits(Variable)Checksum(Optional)End"V"The F ull ASC
The checksum of Code-39 isoptional and made as the sum module43 of the numerical value of the datadigits.By setting Enable, checksum andwill be trans
ReadFormatChecksum VerificationChecksum TransmissionSpare FunctionFormatData Digits(Variable)Checksum(Optional)Generally, the Interleaved 2 of 5symbol
Because, the start and end ofinterleaved 2 of 5 code is not olny onepatten in symbol. In order to preventpartial reading, it is recommand to usethe fi
ReadChecksum VerificationChecksum TransmissionSpare FunctionFormatData Digits(Variable)Checksum(Optional)The checksum is made as thesum module 10 of t
Refer to /27, /35.Truncate LeadingBBG*BBG*(Range:0010-1510)Truncate EndingBBH*BBH*(Range:0010-1510)Min. Code LengthBBE*BBE*(Range:0010-5610)Max. Code
Installation1) First of all, you must make sure that the power is disconnectedform your equipment before connecting the scanner. Beside, youalso have
ReadChecksum VerificationChecksum TransmissionSpare FunctionFormatData Digits(Variable)Checksum(Optional)The checksum is made as thesum module 10 of t
Refer to /27, /35.Truncate LeadingBBK*BBK*(Range:0010-1510)Truncate EndingBBL*BBL*(Range:0010-1510)Min. Code LengthBBI*BBI*(Range:0010-5610)Max. Code
ReadChecksum VerificationChecksum TransmissionSpare FunctionFormatData Digits(Variable)Checksum(Optional)The checksum is made as thesum module 10 of t
The code length of Post 2 of 5 isalways fixed at 11. Therefore, codelength of Min. and Max. is also factorydefault is 11.Refer to /27, /35.Truncate Le
ReadSame Start/End PairStart/End TransmissionChecksum VerificationStart/End Symbol TypesFormatStart Data Digits(Variable)Cheksum(Optional)EndThe Codab
Refer to /35.Refer to /27, /35.Checksum TransmissionDisableGKA*GKA*EnableGKB*GKB*Truncate LeadingBBS*BBS*(Range:0010-1510)Truncate EndingBBT*BBT*(Rang
ReadAppendChecksum VerificationChecksum TransmissionFormatFormatData Digits(Variable)Checksum(Optional)The Code-128 can be translatedto U CC/EAN-128 f
Concatenation Data: This featrure isonly used for UCC/EAN-128 format.This C oncatenation Data means youcan re-assign second or after a FNC1for your u
ReadAppendChecksum VerificationChecksum TransmissionSpare FunctionFormatData Digits(Variable)Checksum1(Optional)Checksum2(Optional)This function which
Refer to /27, /35.Truncate LeadingBCA*BCA*(Range:0010-1510)Truncate EndingBCB*BCB*(Range:0010-1510)Min. Code LengthBBY*BBY*(Range:0010-5610)Max. Code
Configuration FlowchartString Output FlowchartPreamblePrefixCode NameCode IDCode DataCode LengthSuffixPostambleEnterProgrammingModeFinish ASCIICode or
ReadChecksum VerificationChecksum TransmissionSpare FunctionFormatData Digits(Variable)Checksum1(Optional)Checksum2(Optional)The checksum is presented
Refer to /27, /35.Truncate LeadingBCE*BCE*(Range:0010-1510)Truncate EndingBCF*BCF*(Range:0010-1510)Min. Code LengthBCC*BCC*(Range:0010-5610)Max. Code
ReadChecksum VerificationChecksum TransmissionSpare FunctionFormatData Digits(Variable)Checksum1(Optional)Checksum2(Optional)The MSI/Plessey has one o
Refer to /27, /35.Truncate LeadingBCI*BCI*(Range:0010-1510)Truncate EndingBCJ*BCJ*(Range:0010-1510)Min. Code LengthBCG*BCG*(Range:0010-5610)Max. Code
ReadChecksum VerificationChecksum TransmissionReadChecksum VerificationSpare FunctionFormatData Digits(Variable)Checksum1+2(Optional)Refer to /35.HSAD
Refer to /27, /35.Truncate LeadingBCQ*BCQ*(Range:0010-1510)Truncate EndingBCR*BCR*(Range:0010-1510)Min. Code LengthBCO*BCO*(Range:0010-5610)Max. Code
ReadChecksum VerificationSpare Function2Spare Function1Checksum TransmissionIATA (International Air TransportAssociation)The checksum is presented ass
Refer to /27, /35.Truncate LeadingBCM*BCM*(Range:0010-1510)Truncate EndingBCN*BCN*(Range:0010-1510)Min. Code LengthBCK*BCK*(Range:0010-5610)Max. Code
ReadChecksum VerificationChecksum TransmissionSpare FunctionFormatFormatData Digits(Variable)Checksum(Optional)A Telepen can be transimtted withN umer
Refer to /27, /35.Truncate LeadingBCU*BCU*(Range:0010-1510)Truncate EndingBCV*BCV*(Range:0010-1510)Min. Code LengthBCS*BCS*(Range:0010-5610)Max. Code
Default SettingLength TruncateCodeTypeReadEnableMin.Max.LeadingEndingCodeIDUPC-A3- - 0 0 AUPC-E3- - 0 0 EEAN-133- - 0 0 FEAN-83- - 0 0 FFCode-3930 0 0
Preamble DataPreamble TransmissionPostamble DataPostamble TransmissionBy setting Enable, Preamble willbe appended before the datatransmitted. Refer t
Up to 15 characters can beprogramed for Prefix data. The Prefixdata of string will be placed afterPreamble data and before the barcodedata when it is
Add-on Insertion DataInsertion2 DataAdd-on InsertionInsertion1 DataThe scanner offers 2 characdersof insertion between WPC and add-oncode.FormatWPC Ad
Example Barcode "1234567"PostionData1Data2Insertion12 A BInsertion25 C D1) PROGRAMï Entry programming2) Position1ï 0ï 2ï SET Position1 &quo
Code ID PositionCode Name TransmissionLength TransmissionSpare FunctionCode ID TranslationIf your application want totransmite Code ID, you must set t
PROGRAM*/$%STR*If scanner is operated ininverse barcode reading,use inverse PROGRAM toentry scanner programming.Generally, the scanner can onlyread p
Cable TypeIBM PC, XT, AT & PS/2Function5p Din(M)5p Din(F)6p Mini Din(M)6p Mini Din(F)Clock (Host)1 --- 5 ---Data (Host)3 --- 1 ---Clock (KBD.)---
Cable TypeRS-232CFunction9p D-Sub(F)25p D-Sub(F)8p Din(M)DC Jack(M)TxD2 3 1 ---RxD3 2 2 ---RTS8 5 3 ---CTS7 4 4 ---Shorted4,6 6,20 --- ---Ground5 7 7
Test ChartUPC-A000012345670EAN-13 (ISBN) with Add-on 59789572216675 00420(ISBN: 9572216678)Code-39 (Full ASCII Code)* CODE39 T+E+S+T*(Full ASCII Code
Test ChartCodabar/NW7C 98765D D 43210AMSI/Plessey10558302 5CODE-11886264777973 3UK/Plessey16520003546 1TelepenTELEPEN Test+(Numeric: 57424942534251055
Manual Label LayoutThe scanner must be set by reading the barcode labels inmanual. The discription of label is as follows.* The factory default settin
Operation Manual70
ASCII Code TableL H0 1 0 10 Null NUL DLE1 Up F1 SOH DC12 Down F2 STX DC23 Left F3 ETX DC34 Right F4 EOT DC45 PgUp F5 ENQ NAK6 PgDn F6 ACK SYN7 F7 BEL
Frequent QuestionQ: Why scanner block the keyboard operation?A: Check the cable connection with your equipment, then turn poweron again.Q: If scanner
Q:Could I change scanner into different type interface directly?A: You can change factory interface default for other type interface.By plug different
Komentarze do niniejszej Instrukcji